ODP Solid Splitter Description
ODP Solid Splitter can be used in ODP to be installed on Poles, Walls and inside the Closure Pedestal. The ambient temperature ranges from -25 to 65℃. This particular is specifically used by Telkom Indonesia.
Dimension and capacity
Outside dimension (L x W x H) |
350 x 292 x 91 (mm) | |
Weight (excluding outside box) | 1.7-2.3(kgs) | |
Number of inlet/outlet ports | 3 (pieces) on each side | |
Diameter of fiber cable | Φ8—Φ15 (mm) | |
Maximum capacity
(number of connector ports) |
8 port adaptor | 1 Splitter 1:8 |
16 port adaptor | 2 Splitter (2 x 1:8) |
Main components
No. | Name of components | Quantity | Usage | Remarks |
1 | Housing | 1 set | Protecting fiber cable splices in whole | Internal diameter:
345*293 (mm) |
2 | Splitter 1:8 | 8 port adaptor(1PCS) | Terminal optical distribution | 149*140*12(mm) |
16 port adaptor(2PCS) | ||||
3 | Fiber optic splice tray(FOST) | 1pcs | Fixing heat shrinkable protective sleeve and holding fibers | Suitable for:
Bunchy:12(cores) |
4 | Seal fitting | 1 set | Sealing between FOSC cover and
FOSC bottom |
|
5 | Port plug | 1 pieces | Sealing empty ports | |
6 | Pressure testing valve | 1 set | After injecting air it is used for pressure testing and sealing testing | Configuration as per requirement |
7 | Grounding lead-out device | 1 set | Cable grounding |
Other Products